Fluid Collection Monitoring

From SPNHC Wiki
Revision as of 17:22, 8 May 2019 by EmilyBraker (Talk | contribs) (Source Material)

Jump to: navigation, search

Statement of Purpose

These links and documents contain information about best practices for monitoring fluid collections in natural history collections.

Introduction

Fluid collections should be monitored on a regular schedule to prevent excessive preservative evaporation, detect faulty seals on storage containers or changes in the quality of the preservative, and to maintain collections at desired concentration levels. Monitoring intervals will vary based on staff resources as well as the environmental stability within a particular collection store, however, a general guideline is to monitor fluid collections every six months.

Preventing Evaporation

Preservative evaporation within containers steadily occurs in any collection environment. Several measures can be implemented to slow evaporation rates, such as buffering the collection space from fluctuations in temperature and humidity through use of environmental controls, and placement of the store within an interior space rather than adjacent to exterior walls that are more vulnerable to climactic variation. Use of best practice housing materials can also reduce within-jar evaporation rates. Polypropylene lids are less prone to embrittlement than harder plastics such as Bakelite, and can be lined with a polyethylene or Teflon insert to act as a mild oxygen barrier (96). Use of a film layer (e.g., Teflon, Parafilm) between lid and container or Telfon tape wrapped along the threading on jar mouths can also slow evaporation rates (p. 62). Although common, rubber gaskets used with wire-bail jars are not recommended due to the fact that they may dissolve or embrittle when coming into contact with alcohol, risking contamination of specimens and preservatives in addition to negating the efficacy of the seal.

Risks of Evaporation

Ethanol and water and mixed together form an azeotrope rather than a true solution, resulting in asymmetric evaporation rates. Ethanol evaporates faster from mixture than water, diluting preservative strength over time. When concentrations fall below desired levels, specimens are at risk of degradation. Ethanol’s preservative qualities diminish at concentrations <60%, and specimen cell autolysis, decomposition and deterioration may occur (Notton 2010). At low concentration strengths (<50%), ethanol loses its antiseptic properties, promoting bacterial and fungal growth (Waller and Strang, 1996). Specimens exposed to air from dropping preservative levels are vulnerable to desiccation, salt and solute deposition, and increased risk of mechanical injury.

Topping Up

Preservative requirements vary by collection type. Most vertebrate collections are maintained at 70% ethanol while invertebrate collections have a target range of 75-85% ETOH concentration depending on whether or not organisms are soft-bodied. Preservative strength is a balance – concentrations must be strong enough to serve as an effective biocide (>50% ETOH) yet minimize dehydration to specimens, which experience warping and shrinkage at high concentrations (>80% ETOH).

When fluid levels have noticeably dropped inside jars, it is necessary to add more preservative, or “top up” in order to (1) maintain the desired concentration of the preservative, and (2) ensure that all parts of a specimen remain covered by preservative. It is common practice for collections to routinely top-up through loose approximation of the preservative strength needed to return containers to target concentration, either by adding storage-grade preservative (e.g., 70% ETOH) or by adding full-strength preservative (e.g., 95% ETOH) in an attempt to counteract any evaporation that has already occurred. However, both of these approaches have their drawbacks. For instance, the addition of storage-grade preservative does not account for evaporation that has already occurred in the container, and no amount of storage-grade preservative will return a jar to desired strength, but will instead slowly dilute the solution over time. Conversely, adding full-strength preservative without knowledge of the starting concentration can either (1) over-concentrate the storage solution (causing specimen dehydration, distortion and shrinkage), or (2) fail to bring the solution to the target concentration in the case of extremely diluted preservative. Therefore, the best practice approach to topping up is to measure (1) the starting concentration of the preservative as well as (2) the initial volume of the preservative. Together, these metrics will indicate the correct concentration of preservative necessary to bring the solution to desired concentration. Initial volume is a necessary data point for topping up as it conveys the physical space available within which to increase preservative strength. In the case of highly diluted solutions, it is often necessary to pour off some of the existing preservative in order to create sufficient space for full-strength preservative to act in bringing the solution up to the target concentration. See Notton (2010) for greater detail on this method and the downloadable reference table tool described below.

Topping up Tools

A hydrometer or digital density meter is needed to accurately measure initial preservative concentration while preservative volume can be measured using a dipstick or a jar volume template (provided for download). From these metrics, the necessary concentration needed to return the container to target preservative strength can be calculated. However, individual calculations can be time-consuming when topping up a large collection. Instead, a reference table format is desirable so that technicians can quickly and accurately determine the concentration to be added to jars based on accurate approximations of volume and concentration of the container at hand. Such a tool was developed by Notton (2010) for invertebrate collections, with a version adapted for vertebrate collections available for download that provides step-by-step instructions.

Future Monitoring

Following remedial topping up using the quantitative approach described above, a shorthand monitoring system can be implemented for several monitoring cycles given that variation in concentration should be minimal once all containers are accurately “reset” to target concentration (assuming seals are effective and environmental conditions in the collection store are relatively stable). If all containers are filled to the same benchmark (e.g., neck of jar), a drop in volume is easily detected and quantified based on the divergence from the start level. General rules based on average evaporation rates particular to a store can be implemented (e.g., if volume reduced by ½ inch, add 80% ETOH, if volume reduced by >10% replace seal). After 4-5 shorthand topping up cycles, full monitoring using a hydrometer/density meter and topping up tool should be applied. If episodic monitoring protocols are maintained, this full monitoring protocol should be less intensive than the initial remediation topping up activity.

Contributors

Emily Braker